Sending Us An Oil Sample
Step 1: Obtain sample bottle and label from Ramatek Inc.
Step 2: Properly identify your fluid sample(s) in accordance with the guide below.
Step 3: Send to Ramatek Inc., 2515-50th Ave SE, Calgary AB, Canada, T2B 3R8
Ramatek Label
Client ID _______________________
Equipment make _________________
Engine model ___________________
Unit ID _________________________
Date Sample taken _______________
Oil SAE Grade ___________________
Sample type _____________________
Total Km/Hrs ____________________
Km/hrs on oil ____________________
How to fill out the Ramatek label
Client ID:
Individual or company name and phone number.
Equipment Make:
e.g. Freightliner, Peterbilt, Volvo, International, GMC, Toyota, Ford
Engine Model:
e.g. Cat, ISX, C-14, N-14, Series 60, 3.4 litre 6 cylinder
Unit ID:
A number to identify the engine that the sample came from.
e.g. license plate number, truck number
Sample Date:
The date on which the sample was taken.
Oil SAE Grade:
Type of oil used.
e.g. 5W30, 15W40, 75W90
Sample Type:
Whether it’s an engine oil (E), transmission oil (T), coolant (C), hydraulic oil (H) or gear oil (G).
Total Km/Hrs.
Mileage on the odometer or total accumulated time
Km/Hrs on oil:
Mileage or time since last oil change out.